It will transmit always a preamle 19 on the PRACH. Check the logs of the eNB and adjust the timing
|
|
It will transmit always a preamle 19 on the PRACH. Check the logs of the eNB and adjust the timing
|
|
|
advance until it receives this preamble with a close to 0 delay.
|
|
advance until it receives this preamble with a close to 0 delay.
|
|
|
|
|
|
|
|
-- @florian.kaltenberger - 12 Oct 2015 |
|
### Tx-gain and Rx-gain
|
|
|
|
|
|
|
|
To calibrate the Tx and Rx gain parameter you need to follow this steps :
|
|
|
|
|
|
|
|
*1.You have to first set the attenuation between the eNB and the UE:
|
|
|
|
|
|
|
|
The RSRP of the signal received on UE side should be between -75 and -95 dBm, so you have to set the attenuation to be in this range.
|
|
|
|
(See the screen shot in the Stats windows : RSRP[0] -85.32 dBm)
|
|
|
|
|
|
|
|
*2. The received signal on UE side should not saturate for this you have to play with Rx-gain
|
|
|
|
(See the received signal in the LTE DL SCOPE UE of the scrren shot, also in the stats windows you can see that i am using Rx-gain 105 dB)
|
|
|
|
|
|
|
|
*3 Same way as the Rx-gain you should calibrate the Tx-gain to not saturate the eNB.
|
|
|
|
|
|
|
|
This three values of attenuation, Rx and Tx gain depend from your setup so you need to tune them properly.
|
|
|
|
|
|
|
|
 |