Maintenance of Uplink Time Alignment. Introduced control on TA transmission...

Maintenance of Uplink Time Alignment. Introduced control on TA transmission and TA update application.

- ta_timer at gNB side to control the transmission of TA to the UE. This is now happening every 20 slots.
- when the timer resets gNB is now transmitting the TA whether it is zero or not.
- introduced struct NR_UL_TIME_ALIGNMENT_t to handle configuration of time alignment related parameters.
- UE PHY RX: is now triggered through a flag when to store the TA command, the frame and slot
  when the application should occur.
- UE PHY TX: when the tx frame and slot match the time alignment configuration, it process the TA command and applies the
  TA update
parent 5ac8b6f3
No related branches found
No related tags found
9 merge requests!1757Draft: Use pMAX value in configuration file, instead of hardcoded '23' in asn1_msg.c,!1493fix DL arq errors in UE,!1093Issue in generating NR PRACH for High Speed case,!1074PBCH test case support for non-zero bchpyload,!918Develop nfapi,!847Nr vcd,!782Oai ubuntu docker,!765Develop integration 2020 week 05,!702Add PUSCH-based TA updates