With the introduction of X2AP into develop, the UEs now have to regularly send measurement reports. In the logs of the eNB, we see: [OSA] Mismatch found in integrity for algorithm 2, got e0.a0.c2.66, expecting a5.9c.cb.57 [PDCP] [OSA][RB 1] eNB failed to validate MAC-I of incoming PDU This is a bug in the PDCP layer that uses wrong parameters to compute the integrity. This commit fixes this bug. The function pdcp_is_rx_seq_number_valid was removed. Its processing has been directly integrated into the function pdcp_data_ind. The function pdcp_mark_current_pdu_as_received is not called anymore. Its processing was not used later on, so as of today, not calling it does not introduce any functional change. The function pdcp_validate_security takes now as parameters both SN and HFN. Same for the function pdcp_get_next_count_rx. Useless constants PDCP_SN_5BIT, PDCP_SN_7BIT and PDCP_SN_12BIT have been removed. The compilation option ENA...